Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer

Product Details
Customization: Available
Customized: Customized
Structure: Desktop
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 13485
Export Year
2010-06-18
  • Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
  • Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
  • Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
  • Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
  • Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
  • Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
Find Similar Products

Basic Info.

Model NO.
Med-L-1020
Material
Steel
Certification
CE, ISO
Application
School, Hospital, Lab
Type
Measurement Type
Fully Automatic Chemistry Analyzer
Test Speed: 200 Tests Pur Hour
Biochemistry Analyzer
Colorimetry, Turbidimetry
Blood Chemistry Analyzer
42 Sample Positions, Random Access of All Samples
Sample Volume
2-50UL, 0.1UL Increment
Reagent Tray
25 Reagent Positions
Reagent Volume
R1:25-300UL, R2:10-150UL, 0.1UL Increment
Reaction Tray
Rotating Tray, 120 Cuvettes
Reaction Volume
180-500UL
PC Operating System
Windows XP or Above
Fully Chemistry Analyzer Usage
Use for Medical Clinic
Transport Package
Standard Packing for Export
Specification
CE, ISO
Trademark
MeCan
Origin
Guangzhou China
Production Capacity
10000 Set/Year

Product Description

Automatic Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer

200 Tests / Hour Fully Automatic Chemistry analyzer

Model: Med-L-1020


Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer

Overall Performance of the Chemistry analyzer:
Equipment type        Fully automatic discrete, STAT priority
Analysis rate          Constant speed 200T/H (without ISE)
Test principle          Colorimetry, turbidimetry
Analysis method       End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration
 
Sample System
Sample Tray          42 sample positions, random access of all samples
Sample Volume       2-50ul, 0.1ul increment
Sample probe         Liquid level detection, the remaining detection, collision protection etc.
Sample Containers    Sample cups, Micro tube, Original blood-collection tube, etc.
 
Reagent System
Reagent Tray         25 reagent positions
Reagent Volume      R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe        Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration    4-15ºC, independent power supply, 24-hour non-stop refrigeration
 
Reaction System
Reaction Tray        Rotating tray, 120 cuvettes
Cuvette             Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume     180-500ul
Incubation system    Bi-directional liquid-air device
Temperature         37ºC±0.1ºC with real-time display
 
Optical System of the Biochemistry analyzer
Light source           12V35W halogen lamps, over 2000 hours
Photoelectron road     after spectrophotometry
Wavelength           340,405,450,510,546,578,630,700nm
Absorbance range     0-3.500Abs
Resolution            0.0001Abs
 
Operating System of the Automatic Biochemistry Analyzer
PC operating system       Windows XP or above
Analysis control software      English version graphical operating software
Report printing            Report formats support the user-defined mode, QC and state information etc.
System connection        RS-232
 
Working Conditions of the Clinical Chemistry analyzer:
Power supply             AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature     15-30 ºC
Humidity                 35-80%
Water consumption        5L/Hour
Dimension                Bench top: 750mm*520mm*600mm
Weight                   45KG

***************************************************************************
We offer serial Medical Laboratory Analyzers incuding 240Test/H 300Test/h, 400Test/h automatic Chemistry analyzers and Semi-Automatic Biochemistry analyzers:

 
Semi-Auto Chemistry Analyzer   (Cheapest Model)
Model: MCL-301

Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
6 detecting wavelengths: 450-492-510-546-578-630nm
Up to 70 test items
Analytical modes: end-point, absorbance.
Large LCD. menu operation, hospital and patient information editing available
Inner thermal-sensitive printer. English comprehensive report available, including refer range
Memory for 10000 sample results
Few reagent needing, low detecting cost.
Open reagents 
 
Specification of the Semi-auto chemistry analyzer:
Test project ≥70
Wavelength 450,492,510,546,578,630nm
Flow cell 32uL,quartz glass
Liquid volume 200-3000uL
Resolution 0.001Abs(display),0.0001Abs(calculation)
Carryover <1%
Repeatability <1%
Printer Internal thermal-sensitive printer, 58nm paper width
Display 240*64LCD
Communication RS-232 serial cable
Power supply 220\110VAC±15%,50\60Hz 80W
Temperature 15ºC-30ºC wet≤90%
Dimension 380mm(L)*330mm(W)160mm(H)
Weight 7Kg

Semi-Auto Chemistry Analyzer   (Most Popular Model)
Model: MCL-302B
Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer
Feature  of the semi auto chemistry analyzer
7 inch Color LCD , Touch screen 
Flow cell and Cuvette test mode compatible 
Real time curve showing 
7 wavelength , 90 test item pre-programmed
Memory for 10,000 sample results
Light source hibernate function making lamp life longer 
RS232 interface, PC connecting
 
Specification:
Test mode: Kinetic, End point, Two point, Absorbance
Wavelength: 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position 
Wavelength precision: ±2 nm, width ≤ 10nm
Absorbance range: 0~4.500 Abs
Absorbance precision: outside 0.0001 Abs , inside 0.00001 Abs
Carry over: < 1%
Repeatability CV: < 1%
 
Incubator: 37ºC, 30ºC, 25ºC, Precision : ±0.1ºC
Sample volume: 0~3000 uL (≥500uL recommend) 
Data Storage: ≥10000
Quality control curve:  , SD, CV%, L-J quality control curve for every test item
Flow cell: 32 uL quartz glass, 10 mm
Lamp: Philips 6V 10W Halogen Lamp with long life 
Screen: 7 inch color LCD 
CPU: ARM series high speed micro CPU 
Printer: Internal thermal sensitive printer
Interface: RS-232 
Work Environment: Temperature 0ºC ~ 40ºC, Humidity: ≤80% 
Power supply: 100~240VAC, 50-60Hz, 100VA
Dimension: 340(L)*270(W)*160(H)
Weight: 5 kg


Welcome to Contact us for Automatic Blood Chemistry Analyzer 200 Tests/H Fully Automatic Biochemistry Analyzer with CE and Semi-auto chemistry analyzer.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More