Good quality Patient Monitor in hot sales
MED-PM-9000C
8" color TFT LCD screen,resolution 800*600
Lightweight: 1.35KG(with battery)
Waterproof design, Resistance to dropping (1 meter)
Low power consumption, fanless structure which creates no noise.
Support external 13-20V DC power, continously working for 5.5 hours above on battery backup,full charge with 2.5 hours, suitable for Ambulance,Emergency Transport
Display mode: Big font, trends review, 7 leads ECG waveform on same screen, and etc.
15 kinds of arrhythmia analysis, 15 kinds of drug concentration analysis
Anti-electrosurgical unit(300W),anti defibrillator (360J), suitable for Operating Room, General Ward. Digital SpO2 technology,excellent anti-interference performance, low perfusion (0.1%)
Technical Specifications
ECG
Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V
Wave form 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Wave form 1 ch
Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,
20mm/mV, auto
HR and Alarm Range Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ±1% or±1bpm, which is greater
Resolution 1 bpm
Sensitivity > 200 (uVp-p)
Differential Input Impedance > 5 MΩ
CMRR Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range ±8 m V ( Vp-p )
Bandwidth Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Calibration Signal 1 (mVp-p), Accuracy:5%
ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET,
BIGEMINY, TRIGEMINY, R ON T, VT>2,
BRADY, MISSED BEATS, PNP, PNC,
Alarm Available,Review Available
Alarm Type SYS, DIA, MEAN Measuring and alarm range Adult Mode
SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode
SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode
SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg
Resolution 1mmHg
Accuracy Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization intervalabout 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate Measuring and Alarm Range 20~300 bpm
Resolution 1bpm
Accuracy ±3bpm
Respiration
Method Impedance between R-F(RA-LL)
Differential Input Impedance > 2.5 MΩ
Measuring Impedance Range 0.3~3 Ω
Base line Impedance Range 200~4 KΩ
Bandwidth 0.1~2.5Hz
Resp. Rate Measuring and Alarm Range
Adult 0 ~ 120 Brpm
Neo/Ped 0 ~ 150 Brpm
Resolution 1 Brpm
Accuracy ±2 Brpm
Apnea Alarm 10 ~ 40 S
TEMP
Channel 2
Measuring and Alarm Range 0 ~ 50ºC
Resolution 0.1ºC
Accuracy ±0.2ºC
Actualization intervalabout 1 Sec.
Average Time Constant < 10 Sec.
NIBP
Method |
Oscillometric |
Mode |
Manual, Auto, STAT |
Measuring Interval in AUTO Mode |
1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180,
240,480 (Min) |
Measuring Period in STAT Mode |
5 Min |
Pulse Rate Range |
40 ~ 240 bpm |
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature