Multi Parameter Signal Patient Simulator Medical ECG Simulator

Product Details
Customization: Available
Certification: CE
Product Name: ECG Simulator Patient Simulator
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 13485
Export Year
2010-06-18
  • Multi Parameter Signal Patient Simulator Medical ECG Simulator
  • Multi Parameter Signal Patient Simulator Medical ECG Simulator
  • Multi Parameter Signal Patient Simulator Medical ECG Simulator
  • Multi Parameter Signal Patient Simulator Medical ECG Simulator
  • Multi Parameter Signal Patient Simulator Medical ECG Simulator
  • Multi Parameter Signal Patient Simulator Medical ECG Simulator
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
MCS0398
Display
3.5-Inch Color TFT Touch-Screen
Size
18.86 Cm(L)*12.50 Cm(W)*4.32 Cm(H)
Altitude
2000m
Accuracy
2%
Transport Package
Standard Packing for Export
Specification
standard size
Trademark
Mecan
Origin
Guangzhou, China
Production Capacity
10000set/Year

Product Description

 Multi Parameter Signal Patient Simulator Medical ECG Simulator

Model:MCS0398
Multi Parameter Signal Patient Simulator Medical ECG Simulator

Product Description
Introduction
It is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature , 2-channel IBP or 4-channel IBP, the default is 4-channel IBP. And it can be tested in where the monitor is used.


Parameters
ECG:
Conventional: All leads have the same voltage with the II-lead as the reference
Amplitude: 0.5, 1.0, 1.5 and 2.0mV
ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV


Arrhythmia:
ATRIAL: Atrial Fib(coarse), Atrial Fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PAC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, R on T Left Ventricular Focus, Right Ventricular Focus PVC2, Early Right Ventricular Focus PVC2, R on T Right Ventricular Focus, Multifocal PVC
Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block     


Four IBP Channels:
The default: 00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Ventricle 25/00
Channel 2: Artery 120/80, Radial 120/80,  Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 3: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 4:
Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Man Swan-Ganz: press ENTER key to change every time
Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4: P4 tracks the static pressure levels of P3


Respiration:
Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
Baseline impedance: 500, 1000, 1500, 2000Ω
Apnea: 12 s, 22 s, 32 s


Temperature:
Four temperature: 0ºC(32°F), 24ºC( 75°F), 37ºC(98.6°F), 40ºC(104°F)

Simulate the signal of square,triangle, pulse and sine with adjustable frequency.
Simulate the pacemaker signal.
Simulate the signal of standard ECG calibration.
Including the ECG waveforms of ANSI/AAMI EC13.

 
Accessories
Standard accessories a power adapter(9V/1000mA(CE), 220V input), an User manual of MS400, a plastic bag of 200mm * 150mm, a packaging box, a plastic packaging.
Optional accessories a power adapter(15V/1000mA)(UL), 110V input), a power adapter(15V/1000mA, 220V input) , a temperature cable, an IBP cable, a CD disk(including a case conversion software)

Multi Parameter Signal Patient Simulator Medical ECG Simulator

Multi Parameter Signal Patient Simulator Medical ECG SimulatorMulti Parameter Signal Patient Simulator Medical ECG Simulator
 

 

Company Profile
Multi Parameter Signal Patient Simulator Medical ECG SimulatorMulti Parameter Signal Patient Simulator Medical ECG SimulatorMulti Parameter Signal Patient Simulator Medical ECG SimulatorMulti Parameter Signal Patient Simulator Medical ECG SimulatorMulti Parameter Signal Patient Simulator Medical ECG Simulator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More