ICU Anesthesia Machine Operating Room Anesthesia Unit Anesthesia Equipment
Model:MCA-820
This MCA-820 Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient's respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.
Na Lime Tank: Equipped with international advanced one-piece soda lime cans,it can be fast replaced with hands and withstand temperatures up to 134ºC
Circuit: Metal integrated breathing circuit, Perfect function of gas sealing under high temperature disinfection, and easy to cleaning and disinfected.
Flowmeter: 4-Tubes flowmeter; 1. Assure that O2 output not lower than 20% 2. NO2 automatically off while O2 deficiency
Vaporizers:Setting Range: 0.5~5%
What is the technical data of our hospital anesthesia ?
Physical specifications | |
Screen | 5.7 '' color LCD Display Screen |
Suitable | Adult & Child |
Mode | pneumatically powered and electrically controlled system |
Working Mode | Closed; Semi-Closed; Semi-Open |
Circuit | Breathing circuit integrated standards |
Flowmeters | 4 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; |
Trolley | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Drawer unit | ONE drawers totally extractable |
Technical Specifications | |
Gas requirement | Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa. |
safety valve | <12.5 kPa |
Respiratory Rate | 1~99bpm |
oxygen concentration in the mixed gas N2O/O2 | > 21% |
Oxygen Flush | 25~75 L/min |
modes of ventilation | IPPV, SIPPV, IMV, SIMV, VCV, MANUAL PEEP SIGH |
Inspiratory trigger pressure | -1.0kPa ~ 2.0 kPa |
IMV frequency | 1-12 s/min |
I/E Ratio | 4:1 ~ 1:4, Has the inverse ratio ventilation |
Tidal Volume | 0 ~ 1500 ML |
Inspiratory Plateau | 0~1s |
PEEP | 1-10 hPa |
Maximum safety pressure | ≤ 12.5 kPa |
Ptr | -1.0-1.0 hPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating |
Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa ±0.2 kPa |
Tidal volume alarm: Audible and visual and with yellow and red color indicating | upper alarm: 50 to 2000ml, lower alarm: 0~1500ml |
Oxygen concentration alarm: Audible and visual and with yellow and red color indicating | upper alarm: 21% ~100%; lower alarm:10%~80% |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately |
Alarm Time: keep >120s | |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. | |
Operating conditions | |
Ambient temperature: | 10 ~ 40oC |
Relative humidity: | no higher than 80 % |
Atmospheric pressure: | 860 hPa ~ 1060 hPa |
Power requirement: | 220-230 Vac, 50/60 Hz; |
Attention: the AC power supply used for the anesthesia machine must be well grounded. | |
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. | |
Storage | |
Ambient temperature | -15oC ~ +50oC |
Relative humidity | no higher than 95 % |
Atmospheric pressure | 86 kPa ~ 106 kPa. |
It should be stored in a room without corrosive gas and well ventilated | |
Package | |
packaging box | comply with the requirement of GB/T 15464 |
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation | |
Moisture protection and rain protection to ensure that product is protected from natural damage. | |
Safty & Alarm | |
Oxygen Alarm | It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa |
Ventilation Volume Alarm | Lower: 0~12L/Min; Up: 18L/ Min |
Power Alarm | It Alrmas while AC and DC supply failure ; Keep alraming time: >120s |
Air Tract Pressure Alarm | Lower: 0.2kPa ~5.0 kPa; Up: 0.3kPa ~ 6.0kPa |
STANDARD CONFIGURATIONS | |
QTY | NAME |
1 set | Main unit |
1 set | Built in ventilator |
1 set | 4-tube flow meter |
1 set | vaporizer |
1 set | Patient circuit |
1 set | bellow |
1 set | Na lime tank |
1 set | Diaphragm electronic sensor |
1 pc | Oxygen pressure reducer |
2 pcs | A leather bag ( Blue) |
5 pcs | Threaded pipe |
2 pcs | mask |
1 set | Oxygen probe |
1 set | Tools with the machine |
1 set | User Manual (English Version) |
Optional | Patient Monitor |