Classification: Imaging Diagnostic Equipment
Type: ECG
Certification: CE, ISO13485
Lead Mode: 5 Leads (R, L, F, N, C or Ra, La, Ll, Rl,V)
Lead Selection: I, II, III, AVR, Avl, Avf, V
Wavef Orm: 2 CH
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MED-PM-9000
Resolution
1 Bpm
Sensitivity
> 200 (Uvp-P)
Method
Impedance Between R-F(Ra-Ll)
Bandwidth
0.1~2.5Hz
Channel
2
Accuracy
+-2% or 1mmhg Which Is Greater
Label
Art, PA, Cvp, Rap, Lap, Icp, P1, P2
Transport Package
Standard Packing for Export
Specification
CE, ISO
Trademark
Med Equipment
Origin
Guangzhou, China
Production Capacity
10000set/Year

Product Description

Med-Pm-9000 portable 12" Patient Monitor,good price china have stock

MED-PM-9000 

12.1" color TFT screen
Multichannel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
 
Alarm review, arrhythmia review
Patient info. Input
Antidefibrillation design
NIBP over pressure protection
Plugin rechargeable battery, AC/DC available.
Supporting wire or wireless network.
 
Technical Specifications
 
ECG
 
Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection                       I, II, III, avR, avL, avF, V
Wavef orm                           2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL)
Lead selection                       I, II, III,
Wave form                          1 ch
Gain                                     2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
 
HR and Alarm Range                Adult    15 ~ 300 bpm
                                    Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                          1 bpm
Sensitivity                          > 200 (uVp-p)
Differential Input Impedance         > 5 MΩ
 
CMRR                                   Monitor > 105 dB
                                    Operation > 105 dB
                                    Diagnosis > 85 dB
Electrode offset potential            ±300mV
Leakage Current                     < 10 uA
Baseline Recovery                   < 3 S After Defi.
ECG Signal Range                    ±8 m V ( Vp-p )
 
Bandwidth                           Surgery    1 ~ 20 Hz
                                      Monitor     0.5 ~ 40 Hz
                                      Diagnostic  0.05 ~ 130 Hz
Calibration Signal                     1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                                          PNP, PNC,Alarm Available,Review Available
 
 
Respiration
 
Method                             Impedance between R-F(RA-LL)
Differential Input Impedance         > 2.5 MΩ
Measuring Impedance Range        0.3~3 Ω
Base line Impedance Range         200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                          Measuring and Alarm Range
                                    Adult 0 ~ 120 Brpm
                                    Neo/Ped 0 ~ 150 Brpm
                                    Resolution 1 Brpm
                                    Accuracy ±2 Brpm
 
Apnea Alarm                        10 ~ 40 S
 
NIBP
 
Method                            Oscillometric
Mode                              Manual, Auto, STAT                       
Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range                         40 ~ 240 bpm
Alarm Type                          SYS, DIA, MEAN
 
Measuring and alarm range      Adult Mode
                                    SYS 40 ~ 270 mmHg
                                    DIA 10 ~ 215 mmHg
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg
                                    DIA 10 ~ 150 mmHg
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg
                                    DIA 10 ~ 100 mmHg
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg
 
Accuracy                        Maximum Mean error ±5mmHg
                                 Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg
                                 Pediatric Mode 240±3 mmHg
                                 Neonatal Mode 147±3 mmHg
 
SpO2
Measuring Range                0 ~ 100 %
Alarm Range                    0 ~ 100 %
Resolution                      1 %
Accuracy                        70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout        1 Sec.
Alarm Delay                      10 Sec.
Pulse Rate                        Measuring and Alarm Range 20~300 bpm
                                  Resolution       1bpm
                                  Accuracy ±3bpm
 
TEMP
 
Channel                          2
Measuring and Alarm Range        0 ~ 50 ºC
Resolution                        0.1 ºC
Accuracy                            ±0.2 ºC
Actualization intervalabout         1 Sec.
Average Time Constant            < 10 Sec.
 
IBP
 
Label                            ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg
                                 PA -6 ~ 120 mmHg
                                 CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                 P1 / P2-10 ~ 300 mmHg
 
 
Press Sensor                    Sensitivity 5  uV/V/mmHg
                                 Impedance 300-3000Ω
 
Resolution                       1 mmHg
Accuracy                         ±2% or 1mmHg which is greater
Actualization interval              about 1 secretary
 
 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
 
Medical Euiqpment
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Hospital Furniture and Surgical Equipment
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
X-Ray Machine and Ultrasound Scanner
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Obstetric Gynaecology Centre and Rehabilitation Therapeutic Apparatus
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Dental Clinic Equipment and Ophthalmoscope
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Laboratory Equipment
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Sterilizer & Disinfection Products
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Mortuary Equipment
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Homecare Product
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Veterinary Equipment and Education Equipment
Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock
Why Choose MeCan








Med-Pm-9000 Portable 12&quot; Patient Monitor, Good Price China Have Stock

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now