Customization: | Available |
---|---|
Type: | Dental |
Function: | Biological Regulatio |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. | Part name |
1 | Host |
2 | Energy knob |
3 | Handwriting pen |
4 | Display screen |
5 | Frequency knob |
6 | SD card slot |
7 | Therapeutic handle (therapeutic head) |
8 | Air outlet |
9 | Air intake and fan |
10 | Foot switch |
11 | Power switch |
12 | Fuse wire |
13 | Power port |
14 | Handle port |
15 | Foot switch port |
16 | Product nameplate |
4 Product main features
Themain product featuresof O-Wave I asfollow: a) Thehumanengineeringdesignprovidessettingandoperatesconveniently; b) 7inchescolorcrystalChineseandEnglishtouchscreendesign,intuitiveandclear; c) Importpowersource,toensureinstantshockoutputeffect; d) Energyandfrequencyselection,conformtotreatmentdemand; e) Singleordualoutputisoptional,andprovidesavariousprofessionalprobe; f) Thereare7adjustablepresetreferencesolutions; g) Adoptaportabledesign.
5 Product requirements andmain parametric description
5.1Product requirements
1)Working powersupply: 100-240VAC,frequency: 50/60Hz
2)Environmental requirements
5.2Product main technical parametric description Pulse energy levels: 60-185mJ (at the applicator),freely adjustablein 10mJ increments at 22Hz max. 90 mJ at 16Hz max. 120mJ at 10Hz max. 185mJ;The output tolerance is ±40mJ,TheCV is ±5%
Working frequency 1~22Hz,adjustable in 1Hz increments
Work pattern 4continuous capture modes(shots/4/8/12 pulses)
Reference operatingversion 7preset operationversions, canbe adjustable
Suggestion for treatment parts Exceeds25preset treatment suggestion
Control function All function implemented by touching operation; rotary knob controls energy and frequency; multi-directional footswitch coordinateswith therapeutic handle operation.
Product boundarydimension
290×240×130mm(length/width/height)
Product weight 2.07kg(do not contain therapeutic handle andfootswitch)
The description of therapeutic handle/therapeutic headto shockwave The therapeutic handle design conforms to human engineering, combines anodized aluminium shell with fan cooling, produces electromagnetic force drive projectile working by means of coil electrical over. The boundary dimension is 23cm, diameter is 5cm (the maximum); the minimum service life of therapeutic handle is 2,000,000 times (the calculation according to a number of strokes); only need to do some daily maintenance and nursing for appearance, it is recommended to use cleaning with medicinal alcohol; the therapeutic head divided into 3 specifications: 6/15/25mm (diameter); the minimum service life of each therapeutic head is 150,000 times (the calculationaccordingto a number of strokes).
Power consumption 100/240VAC 50/60Hz,300VA
The fuse (wire fuse) specification 250V/10A
The requirement of therapeuticheadtemperature Theexternal temperature of therapeuticheadof the O-wave I is not greater than 48ºC.
Electrical safety classification Type BF applied parts