Hemodialysis Machine Kidney Dialysis Machine Price

Product Details
Customization: Available
Customized: Non-Customized
Certification: ISO13485
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 13485
Export Year
2010-06-18
  • Hemodialysis Machine Kidney Dialysis Machine Price
  • Hemodialysis Machine Kidney Dialysis Machine Price
  • Hemodialysis Machine Kidney Dialysis Machine Price
  • Hemodialysis Machine Kidney Dialysis Machine Price
  • Hemodialysis Machine Kidney Dialysis Machine Price
Find Similar Products

Basic Info.

Model NO.
MC-DYM-02
Colour
White
Type of Body Fluid-Processing Device
Human Blood Processor
Product Name
Double Pump Hemodialysis Machine
Screen
LCD Touch Screen
Application
Hemodialysis, Hemoperfusion, ISO, UF, etc.
Power Supply Voltage
AC220V±10%
Frequency
50Hz ~ 60 Hz
Weight
About 90kg
Power
1500W
Temperature
35.0ºC~39.0ºC
Resolving Rate
0.1ºC
Conductivity
13ms/Cm~15.5ms/Cm
Transport Package
Standard Package for Export
Specification
370mm× 340mm × 1570mm
Trademark
Mecan
Origin
Guangzhou
HS Code
9018904000
Production Capacity
1000

Product Description

Hemodialysis Machine Kidney Dialysis Machine Price

Model : MC-DYM-02 / MC-HD01

Hemodialysis Machine Kidney Dialysis Machine Price


What is the detail of our hemodialysis machine?

Main technical parameter
Volume (length× width ×height):370mm×340mm ×1570mm
Weight: about 90kg 
Power supply voltage: AC220V±10% 
Frequency: 50HZ ~ 60 HZ
Power: 1500W

 

Blood pump/spare pump
Flux: 15 ~ 340ml/min (D 6mm)
Flux: 20 ~ 460ml/min (D 8mm)

Heparin pump:
Flux: 0.1ml/h~10ml/h(±5%) 
Flux: Precise: 0.1ml/h
Injector size: 20ml/30ml/50ml 10ml/20ml/30ml (selectable)

Hemodialysis Machine Kidney Dialysis Machine Price

Arterial pressure
display scope:-300mmHg~+300mmHg (±10mmHg)

Venous pressure
display scope:-50mmHg~+300mmHg (±10mmHg)
Dialysate flow:300ml/min~800ml/min linearity adjustable(+10%)(-5%)
Temperature:35.0ºC~39.0ºC
Resolving rate:0.1ºC
Conductivity:13mS/cm~15.5mS/cm(±0.1 mS/cm)
UF flow scope: 0~1800ml/h(±30ml/h )
0~4000ml/h(optional)
ISO UF flow scope:0~2000ml/h(±30ml/h)
TMP
Scope:-100mmHg~+600mmHg (±20mmHg)
Blood leakage monitor: over 1ml blood per liter dialysate (flow:500ml/min)
Blood level monitor: ultrasonic sensor

 

Air bubble monitor
Infrared and response threshold value:Single air bubble of 200u I exists when Blood flux is 200ml/min
Inflow pressure:0MPa~0.6MPa
Inflow temperature: 5ºC~30ºC
Environment temperature: 10ºC~30ºC, Relative humidity≤70%
Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid)
Hot rinse: 80ºC
Back-up power supply: last for 15-30min after electric-cut.

 

Function
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.
Touch screen was equipped and it can show Naand UF profiles;In addition,the functions ie.backup power supply,Kt/V,HCO3adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.

 



What is the clinical application of our Kidney Dialysis Machine?

Clinical Application
√ Hemodialysis Therapy
√ Pure ultrafiltration Therapy
√ Hemoperfusion Therapy
√ Plasma exchange Therapy
√ Na+and UF profiling
Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect.

 

Kt/V function
The sufficiency of dialysis can be reflected by Kt/V.
HCO3 adjustment function:
Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient's state of illness. 
Backup power-supply:
It can last for 15-30 minutes after power cut off.

 

Pyrogen filter port
Completely filtrating the remained bacteria and endotoxin.(optional)


Net connection
One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)

Model : MC-DYM-02 &  MC-HD05
Hemodialysis Machine Kidney Dialysis Machine Price

Function
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.
Touch screen was equipped and it can show Naand UF profiles;In addition,the functions ie.backup power supply,Kt/V,HCO3adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.

What is the clinical application of our Kidney Dialysis Machine?
Clinical Application
1. Hemodialysis Therapy
2. Pure ultrafiltration Therapy
3. Hemoperfusion Therapy
4. Plasma exchange Therapy
5. Na+and UF profiling
Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect.

Kt/V function
The sufficiency of dialysis can be reflected by Kt/V.
HCO3 adjustment function:
Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient's state of illness.
Backup power-supply:
It can last for 15-30 minutes after power cut off.

What is the detail of our hemodialysis machine?
 
Main technical parameter
Volume (length× width ×height):370mm×340mm ×1570mm
Weight: about 90kg
Power supply voltage: AC220V±10%
Frequency: 50HZ ~ 60 HZ
Power: 1500W

Blood pump/spare pump
Flux: 15 ~ 340ml/min (D 6mm)
20 ~ 460 ml/min (D 8mm)
Heparin pump:
Flux: 0.1ml/h~10ml/h(±5%)
Precise: 0.1ml/h
Injector size: 20ml/30ml/50ml 10ml/20ml/30ml (selectable)

Arterial pressure

display scope -300mmHg~+300mmHg (±10mmHg)


Venous pressure
display scope:-50mmHg~+300mmHg (±10mmHg)
Dialysate flow:300ml/min~800ml/min linearity adjustable(+10%)(-5%)
Temperature:35.0ºC~39.0ºC
Resolving rate:0.1ºC

Conductivity:13mS/cm~15.5mS/cm(±0.1 mS/cm)
UF flow scope: 0~1800ml/h(±30ml/h )
0~4000ml/h(optional)
ISO UF flow scope:0~2000ml/h(±30ml/h)
TMP
Scope:-100mmHg~+600mmHg (±20mmHg)
Blood leakage monitor: over 1ml blood per liter dialysate (flow:500ml/min)
Blood level monitor: ultrasonic sensor

Air bubble monitor
Infrared and response threshold value:Single air bubble of 200u I exists when Blood flux is 200ml/min
Inflow pressure:0MPa~0.6MPa
Inflow temperature: 5ºC~30ºC
Environment temperature: 10ºC~30ºC, Relative humidity≤70%
Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid)
Hot rinse: 80ºC
Back-up power supply: last for 15-30min after electric-cut.


Pyrogen filter port
Completely filtrating the remained bacteria and endotoxin.(optional)

Net connection
One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)


Our hemodialysis machine for kidney in different hospitals worldwide, Paraguay, Nigeria, South Africa, Zimbabwe, Uganda, Kenya, Malaysia etc.

Our hemodialysis in Paraguay
Hemodialysis Machine Kidney Dialysis Machine Price

Our hemodialysis in Nigeria
Hemodialysis Machine Kidney Dialysis Machine Price
Hemodialysis Machine Kidney Dialysis Machine Price

Our hemodialysis in Uganda
Hemodialysis Machine Kidney Dialysis Machine Price

Our hemodialysis in Kenya
Hemodialysis Machine Kidney Dialysis Machine Price

Our hemodialysis in Zimbabwe
Hemodialysis Machine Kidney Dialysis Machine Price

Our hemodialysis in South Africa
Hemodialysis Machine Kidney Dialysis Machine Price

Our hemodialysis in Malaysia

Hemodialysis Machine Kidney Dialysis Machine Price

Hemodialysis Center

Hemodialysis Machine Kidney Dialysis Machine Price

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More