• CPR Medical Simulaids Model Full Body Mannequin
  • CPR Medical Simulaids Model Full Body Mannequin
  • CPR Medical Simulaids Model Full Body Mannequin
  • CPR Medical Simulaids Model Full Body Mannequin

CPR Medical Simulaids Model Full Body Mannequin

Product Name: CPR Medical Model
Package Size: 97*33*58cm+80*30*40cm
G.W.: 30.2kgs
Full Body Manikin: 1 Set
Trauma Limbs: 1 Set
IC Card: 20 PCS /Set
Customization:

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MC-CPR400S-C
Transport Package
Standard Package for Export
Origin
Guangzhou
Production Capacity
1000

Product Description

CPR Medical Simulaids Model Full Body Mannequin

Model: MC-CPR400S-CCPR Medical Simulaids Model Full Body MannequinProduct Description

What is the detail of our full body mannequin?

Features:
1. With all functions of MC-CPR400S
2. Student IC card: IC card can record all the operation and assessment information; can also be used for exam process playback, result evaluation, student documents management 
3. Equipped with trauma limbs, can replace the original limbs to act wound washing, stop bleeding, bandaging, fixation, carrying.

 

Main Components:
1. Full body manikin (1) 
2. Trauma limbs (1set) 
3. Monitor (1)
4. Card reader (1) 
5. IC card (20pcs /set) 
6. Manage software (1)
7. Portable plastic box (1) 
8. Temperature sensing printer (1)
7. CPR operation pad (1) 
8. CPR face shield sheet (50pcs/box)
9. Exchangeable lung bag (5)
10. Exchangeable face skin (1) 
11. Temperature sensing print paper (2 roll)
12. Guide manual (1)

PACKAGE SIZE: 97*33*58cm+80*30*40cm
G.W.: 30.2KGS

 

Other cpr medical models

MC-CPR400S-ACPR Medical Simulaids Model Full Body Mannequin

Features:
1. Simulate standard open airway and sound prompting
2. External breast compression: indicator light display, digital counter display and sound prompting
a) Indicator light display of correct and wrong compression position; digital counter display; sound prompting of wrong compression.
b) Display of correct (at least 5cm) and wrong (less than5cm) compression intensity; digital strip indicator light (yellow, green, red) shows compression depth; counter display; sound prompting of wrong operation.
3. Artificial respiration (Inhalation) indicator light display, digital counter display and sound prompting:
a) Inhalation is ≤500ml/600ml-1000≤, strip indicator light shows inhalation volume; counter display of correct and wrong operations, and sound prompting of wrong operation.
b) Inhalation too quickly or too much result in air entering into stomach; indicator light display; digital counter display; sound prompting.
4. Ratio of compression and artificial respiration: 30:2 (one or two person)
5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration.
6. Operation frequency: at least 100 times per minute
7. Operation methods: exercise operation; examine operation
8. Operation time: counting down device
9. Sound prompting device: volume control; turning on or turning off sound prompting device
10. Print: print operation result
11. Examination of pupil response: mydriasis and myosis
12. Examination of carotid response: simulate spontaneous carotid pulse in compression process
13. Working conditions: Working conditions: Input power is 110-240V or adopts direct current of eight No.1 batteries.

 

Standard components:
1. Full body manikin (1) 
2. Monitor (1) 
3. Portable plastic box (1)
4. Temperature sensing printer (1) 
5. CPR operation pad (1) 
6. CPR face shield sheet (50pcs/box)
7. Exchangeable lung bag (5)
8. Exchangeable face skin (1) 
9. Temperature sensing print paper (2 roll) 
10. Guide manual (1)

PACKAGE SIZE: 97*33*58cm
G.W.: 22KGS

 

 

MC-CPR300SCPR Medical Simulaids Model Full Body Mannequin

Features:
1. Simulate standard open airway and sound prompting
2. External breast compression: indicator light display, digital counter display and sound prompting
a) Indicator light display of correct and wrong compression position; digital counter display; sound prompting of wrong compression.
b) Display of correct (at least 5cm) and wrong (less than 5cm) compression intensity; digital strip indicator light (yellow, green, red) shows compression depth; counter display; sound prompting of wrong operation.
3. Artificial respiration (Inhalation) indicator light display, digital counter display and sound prompting:
a) Inhalation is ≤500ml/600ml-1000ml≤, strip indicator light shows inhalation volume; counter display of correct and wrong operations, and sound prompting of wrong operation.
b) Inhalation too quickly or too much result in air entering into stomach, counter display and sound prompting of wrong operation.
4. Ratio of compression and artificial respiration: 30:2 (one or two person)
5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration.
6. Operation frequency: at least 100 times per minute
7. Operation methods: exercise operation; examine operation
8. Operation time: counting down device
9. Print: print operation result
10. Examination of pupil response: mydriasis and myosis
11. Examination of carotid response: simulate spontaneous carotid pulse in compression process
12. Working conditions: Input power is 110-240V

 

Main Components:
1. Full body manikin (1) 
2. Monitor (1)
3. Portable plastic box (1) 
4. CPR operation pad (1) 
5. CPR face shield sheet (50pcs/box)
6. Exchangeable lung bag (5)
7. Exchangeable face skin (1) 
8. Temperature sensing print paper (2 roll)
9. Guide manual (1)

 

Optional function:
1. Endotracheal intubation
2. Gastrolavage
3. Trauma limbs

PACKAGE SIZE: 97*33*58cm
G.W.: 22KGS

 

MC-CPR300S-ACPR Medical Simulaids Model Full Body Mannequin

Features:
1. Simulate standard open airway and sound prompting
2. External breast compression: indicator light display, digital counter display and sound prompting
a) Indicator light display of correct and wrong compression position; digital counter display; sound prompting of wrong compression.
b) Display of correct (at least 5cm) and wrong (less than 5cm) compression intensity; digital strip indicator light (yellow, green, red) shows compression depth; counter display; sound prompting of wrong operation.
3. Artificial respiration (Inhalation) indicator light display, digital counter display and sound prompting:
a) Inhalation is ≤500ml/600ml-1000ml≤, strip indicator light shows inhalation volume; counter display of correct and wrong operations, and sound prompting of wrong operation.
b) Inhalation too quickly or too much result in air entering into stomach, counter display and sound prompting of wrong operation.
4. Ratio of compression and artificial respiration: 30:2 (one or two person)
5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration.
6. Operation frequency: at least 100 times per minute
7. Operation methods: exercise operation; examine operation
8. Operation time: counting down device
9. Print: print operation result
10. Examination of pupil response: mydriasis and myosis
11. Examination of carotid response: simulate spontaneous carotid pulse in compression process
12. Working conditions: Input power is 110-240V or adopts direct current of eight No.1 batteries.

 

Standard components:
1. Full body manikin (1) 
2. Monitor (1) 
3. Portable plastic box (1)
4. Temperature sensing printer (1) 
5. CPR operation pad (1) 
6. CPR face shield sheet (50pcs/box)
7. Exchangeable lung bag (5)
8. Exchangeable face skin (1)
9. Temperature sensing print paper (2 roll) 
10. Guide manual (1)

PACKAGE SIZE: 97*33*58cm
G.W.: 22KGS

 

MC-CPR230SCPR Medical Simulaids Model Full Body Mannequin

Features:
1. Simulate standard open airway 
2. External breast compression: display device and alarm device
1) Indicator light display of correct and wrong compression; alarm of wrong compression;
2) Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; alarm of wrong compression. Digital strip indicator light (yellow, green, red) shows compression depth;
3. Artificial respiration (Inhalation): display device and alarm device
1) Display of inhalation (≤500ml-600ml≤), strip indicator light shows inhalation volume; alarm of wrong operation
2) Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting.
4. Ratio of compression and artificial respiration: 30:2 (one or two person)
5. Operating cycle: 2times correct respiration, one cycle includes five times of 30:2 (one or two person)
6. Operation frequency: at least 100 times per minute 
7. Operation methods: exercise operation
8. Examination of pupil response: mydriasis and myosis
9. Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse
10. Working conditions: Input power is 110-240V

PACKAGE SIZE: 97*33*58cm
G.W.: 19.5KGS

Send your message to this supplier

*From:
*To:
avatar Miss Sharon Feng
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO 9001, ISO 9000, ISO 13485
Export Year
2010-06-18