Customization: | Available |
---|---|
Type: | Anesthesia Ventilator |
Used for: | Adult |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Specification | ||
Physical Characteristics | ||
Size | 773.5mm×1380mm×598mm | |
Weight | 90kg | |
Entire Machine Maximum Bearing Weight | 160kg |
|
Screen Size: | 8.4" TFT touch screen | |
Resolution | 800 × 600 | |
Handrail Length | 412mm | |
Caster wheel | 4 wheels 4" brakes; | |
Operation Environment | ||
Working Temp | 10~40°C | |
Humidity | ≤93% | |
Power Supply | 100-240V~, 50/60Hz±1Hz | |
Battery Type | Rechargeable Lithium-ion battery | |
Battery Capacity | 4400mAh, 11.1VDC | |
Battery Recharging Time | Maximum 10 hours for charging |
|
Battery backup | 2 hours for continuous working | |
Trace | Waveforms: Pressure-time; Flow rate-time; Capacity-time; ET EtCO2 concentration; EEG Optional: Pressure-volume Loops; Flow-volume Loops; Pressure- flow Loops |
|
Top Plate | ||
Maximum supporting capacity | 20kg |
|
Operational dimensions | 508mm×313mm |
|
Dimensions with Additional Accessory | 508mm×313mm×380mm |
|
Workbench | ||
Maximum supporting capacity |
20kg |
|
Operational dimensions | 472mm×248mm |
|
Dimensions with Additional Accessory | 472mm×248mm×380mm |
|
Interfacing: | ||
USB port | ||
RJ45 | ||
Three auxiliary power output | ||
AC power interface | ||
Equal-potential grounding terminal | ||
DB9 interface | ||
Features | ||
Drawers: | Size:416mm×395mm×170mm Bearing Weight: 1Kg |
|
Gas-bag Sway Brace: | Length: 320mm; Height: 240mm | |
Anesthesia process | Open, semi closed, closed circuit | |
Patients | Designed for adult, pediatric | |
Mode | Manual, Mechanical, Standby | |
Compliance | Compliance Correction | |
Configuration | Possibility of configuration observation | |
Optional | Bypass; Heating; Oxygen sensor; ACGO; AGSS; BIS; CPB; MASIMO EtCO2 (sidestream); MASIMO EtCO2 (mainstream); MASIMO AG (sidestream); Respironics EtCO2 (mainstream); |
|
Ventilator Specification | ||
Ventilation Modes | ||
VCV/VC | Volume-Controlled Ventilation with tidal volume compensation | |
Others | Manual and automatic ventilation | |
Optional | PCV/VPC, SIMV-VC, PSV/ CPAP, SIMV-PC, PRVC, SIMV-PRVC, PSVPro | |
Ventilation principle | Chronometric, volumetric and barometric | |
Ventilation | Electronically controlled& pneumatically driven | |
Driven gas | O2(air: optional) | |
Ventilator Setting ranges | ||
Monitoring parameter | Tidal volume, Inspiratory, expiratory flow, minute volume, frequency, pressure (Pmean, Pplat, Ppeak, PEEP), Oxygen, CO2, N2O and halogenated expiratory concentration, Pressure, oxygen, CO2, N2O and Halogen numerical values, compliance and patient resistance | |
Tidal volume range | 15 ~1500 mL | |
Pressure range (limit) |
10~100 cmH2O |
|
Pressure range (support) |
3~60cmH2O |
|
Respiratory rate | 4~100bpm | |
Inspiratory /Expiratory ratio (I: E) range |
4:1~1:10 |
|
Apnea I: E | 4:1~1:8 | |
Apnea time | 10~30s | |
Apnea pressure | 3~60cmH2O | |
Inspiratory pause | OFF, 5~16% of inspiratory time | |
Inspiratory time | 0.2~5s | |
Inspiratory pressure | 5~70cmH2O | |
PEEP | OFF, 3~30cmH2O | |
Trigger pressure | -20~-1cmH2O | |
Trigger window | 5~90% | |
Trigger flow | 0.2~15 L/ min | |
Flush oxygen | 25~75 L/ min | |
Inspiratory stop level | 5~80% | |
Pressure slope | 0~2.0s | |
Positive End Expiratory Pressure (PEEP) | ||
Type | Integrated, electronically controlled | |
Range | 0~70 cmH2O | |
Ventilator Monitoring Ranges | ||
TV (Inspiratory tidal volume) | 0~3000 mL |
|
TV (Expiratory tidal volume) | 0~3000 mL |
|
MV (Per-minute ventilation amount) | 0~100 L/min |
|
FiO2 (Oxygen concentration) | 18~100% |
|
Airway pressure | -20~120cmH2O | |
PEEP | 0~70cmH2O | |
Ppeak (Airway pressure) |
-20~120 cmH2O |
|
Pmean (Mean pressure) |
-20~120cmH2O |
|
Pplat (Platform pressure) |
0~120cmH2O |
|
I: E (Inspiratory- expiratory ratio) | 4:1~1:12 |
|
Freq (Respiratory rate) |
0~120 bpm |
|
Compl (Compliance) | 0~300 mL/cmH2O | |
Resistance | 0~600 cmH2O/(s/L) | |
EtCO2 | ||
MASIMO EtCO2 (sidestream); | 0~190mmHg, 0~25% (at 760mmHg) Accuracy: ± (0.3%+4% of reading). |
|
MASIMO EtCO2 (mainstream) | 0~190mmHg, 0~25% (at 760mmHg) Accuracy: ± (0.3%+4% of reading). |
|
Respironics EtCO2 (mainstream) | 0~150mmHg, 0~19.7% (at 760mmHg) Accuracy: 0~5.3%: ±0.3%; 5.4~9.2%: ±5% of reading; 9.3~13.2%: ±8% of reading; 13.3~19.7%: ±10% of reading; |
|
AG | ||
MASIMO AG | SEV: 0~25%DES: 0~25%HAL/ ISO/ ENF: 0~25% N2O: 0~100% O2: 0~100% CO2: 0~25% (0~190mmHg) Accuracy: SEV: 0~1%: ± 0.15%; 1~5%: ±0.2%; 5~8%: ±0.4%; DES: 0~1%: ± 0.15%; 1~5%: ±0.2%; 5~10%: ±0.4%;10~15%: ± 0.6%; 15~18%: ±1%; ISO, ENF, HAL: 0~1%: ±0.15%; 1~5vol %: ±0.2%; N2O: ± (2% + 2% of the reading) O2: 0~25%: ±1%; 25~80%: ±2%; 80~100%: ±3%; CO2: 0~15%: ± (0.2% + 2% of the reading); 15~25%: unspecified |
|
Anesthesia depth | ||
BIS | 0.0~100.0 | |
SQI | 0.0~100.0% | |
EMG | 0~100dB | |
ESR | 0.0~100.0% | |
Ventilator Performance | ||
Pressure range at inlet | 0.28~0.6 MPa | |
Peak gas flow | 100 L/min plus fresh gas | |
Flow valve range | 1~100 L/min | |
Flow compensation rage | 200 mL/min to 15 L/min |
|
Inspiratory flow | Maximum inspiratory flow shall not be smaller than 120L/min when gas supply pressure is 280KPa. | |
Range of flow valve | 3~100 L/min | |
Pressure limitation Controlling means for ventilator |
Controlled by the electronic relief valve fitted inside the ventilator; Controlled by the mechanical relief valve fitted inside the ventilator. |
|
Ventilator accuracy | ||
Control accuracy | ||
TV | 15~60 ml: ±10ml; 60~210 ml: ±15ml; 210~1500 ml: ±7% of set value. |
|
PCV | Inspiratory pressure: ±2.5cmH2O or ±7% of set value, whichever the greater. Limiting pressure: ±2.5cmH2O or ±7% of set value, whichever the greater. PEEP: OFF: undefined; 3~30cmH2O: ±2.0cmH2O, or ±8% of set value, whichever is the greater. Supporting pressure: ±2.5cmH2O or ±7% of set value, whichever the greater. Apnea pressure: ±2.5cmH2O or ±7% of set value, whichever the greater. Trigger pressure: ±2.0cmH2O. |
|
Freq | ±1 bpm or ±5% of set value, whichever is the greater. | |
I: E | 2: 1~1: 4: ±10% of reading value; Other ranges: ±25% of reading value. |
|
Apnea I: E | 2: 1~1: 4: ±10% of set value; Other ranges: ±25% of set value. |
|
Tip: Ti | 20%~60%: ±15% of set value; Other ranges: undefined. |
|
Inspiratory time | ±0.2s | |
Inspiratory pause | 20%~60%: ±15% of set value; Other ranges: undefined. |
|
Trigger window | ±10% | |
Trigger flow rate | ±1 L/ min | |
Inspiratory stop level | ±10% | |
O2/ N2O/ Air flow control | 10~100% of the full scale: ±10% of the reading value. Other ranges: undefined. | |
Total flow control | Air balance gas: ≤±3% N2O balance gas: ≤±3% |
|
Backup flow control | Pure Oxygen flow rate is 0~10 L/min: ≤±3%; Others: undefined. | |
Auxiliary flow control | 10~100% of the full scale: ±10% of the reading value. Other ranges: undefined. | |
Monitoring accuracy | ||
TV (expiratory) |
0~60ml: ±10 ml; 60ml ~ 3000ml: ± 20ml or ± 7% of reading value, whichever is greater; Others: undefined. | |
TV (Inspiratory) |
60ml ~ 3000ml: ± 20ml or ± 7% of reading value, whichever is greater; Others: undefined. | |
Paw | -20 cmH2O~120 cmH2O: ±2.0 cmH2O or ± 4% of set value, whichever is greater; Others: undefined. | |
PEEP | 0 cmH2O~70 cmH2O: ±2.0 cmH2O or ± 4% of set value, whichever is greater; Others: undefined. | |
Pmean |
-20 cmH2O~120 cmH2O: ±2.0 cmH2O or ± 4% of setting value, whichever is greater; Others: undefined. |
|
Pplat |
0 cmH2O~120 cmH2O: ±2.0 cmH2O or ± 4% of set value, whichever is greater; Others: undefined. | |
Freq | ±1 bpm or ±5% of set value, whichever is the greater. | |
I: E | 2: 1~1: 4: ±10% of reading value; 4: 1~2: 1 and 1: 4~1: 12: ±25% of setting value; Others: undefined. |
|
MV | 0 L/min~30 L/min: ±1 L/min or ±15% of set value, whichever is greater; Others: undefined. | |
Compliance | 0 ml/cmH2O~250 ml/cmH2O: ±0.5 ml/cmH2O or ± 15% of reading value, whichever is greater; Other ranges: undefined. |
|
Resistance | 0 cmH2O/(L/s)~20 cmH2O/(L/s): ±10 cmH2O/(L/s);20 cmH2O/(L/s)~500 cmH2O/(L/s):±50% of reading value; Other ranges: undefined. | |
Oxygen sensor | ±3% | |
O2/ N2O/ Air flow control | 10~100% of the full scale: ±10% of the reading value. Other ranges: undefined. | |
Total flow control | Air balance gas: ≤±3% N2O balance gas: ≤±3% |
|
Backup flow control | Pure Oxygen flow rate is 0~10 L/min: ≤±3%; Others: undefined. | |
Auxiliary flow control | 10~100% of the full scale: ±10% of the reading value. Other ranges: undefined. | |
Alarm Settings | ||
Tidal volume (expiratory) |
High: 5~1600 ml |
|
Low: 0 ~1595 ml | ||
MV | High: 2~100L/ml | |
Low: 0 ~98L/ml | ||
Inspired oxygen | High: 20~105% | |
Low: 18 ~ 103% | ||
Ppeak | High: 2 ~100cmH2O | |
Low: 0 ~98cmH2O | ||
Apnea alarm | 30s | |
Alarm | Audible and visual alarm; | |
Alarm access | Easy access by shortcut | |
Flow meters | ||
Type | Mechanical flow meter | |
Gas Supply | ||
Pipeline gasses | O2 | |
Optional | O2, Air; O2, N2O; O2, N2O, Air | |
Standby gas-cylinder gasses |
O2, N2O, Air |
|
Pipeline gas connection | NIST |
|
Standby cylinder connection |
PISS |
|
Pressure range at inlet |
280~600 kPa |
|
Filter | 60-80um | |
Features | Switch easily to the other gas without interrupting the ventilation | |
Auxiliary gas supply | O2(optional) | |
Breathing Circuit Specification | ||
System Pressure Gauge | ||
Range | -20~100 cmH2O | |
Accuracy | ± (4% of full scales reading + 4% of reading) | |
Adjustable Pressure Limiting (APL)valve | ||
Range | 1~75 cmH2O | |
Tactile knob indication at | >30 cmH2O |
|
Accuracy: | ±1.0 cmH2O | |
Minimum opening pressure |
0.3 cmH2O (dry), 0.5 cmH2O (humid) |
|
Breathing Circuit Parameters | ||
Compliance | ≤4mL/100Pa Automatically compensates for compression loss with in the breathing circuit in mechanical mode |
|
Volume of CO2 canister | 1500ml |
|
Water Trap | 7mL, easy to be disassembled | |
Feature | Heated at 134 degree, removable, easy to dismantle and sterilize | |
Gas Monitoring | ||
Carbon Dioxide (CO2) Modules | ||
Type | Mainstream ETCO2, Sidestream ETCO2 | |
Method | Infrared absorption | |
Display | Numeric and curve displayed in screen | |
Alarm delay | 1~10s (step size: 1s) | |
Sweep | 6.25 mm/s,12.5 mm/s | |
Anesthetic Agent (AG) Module | ||
Maximum sound pressure for low alarm | 79dB |
|
Measurement type | Side stream | |
Module type | Phasin ISA AG module | |
Accuracy | ±10ml/min or ±10%, whichever is greater | |
Monitored parameters | CO2, N2O, AA, MAC, Paramagnetic O2 and BIS | |
Active AGSS | ||
Feature | High flow, low vacuum | |
Size | 535mm×120mm×155mm | |
Weight | 2.2kg | |
Applies | ISO 80601-2-13 and YY 0635-2 | |
Pressure relief device | Atmospheric pressure compensation port | |
Connector | ISO9170-2 or BS6834 standard connector | |
Flow of suction | 50-80L/min | |
Resistance | 0.75KPa ,75L/min | |
Filter | Stainless steel mesh, with pore size of 60~100μm | |
ACGO | ||
Connector | Taper coaxial fitting of 22mm (outside) and 15 (inside) | |
Back pressure generated at the rear end of anesthesia vaporizer and the front-end of ACGO during quick oxygen charging | <=2kPa |
|
Flush O2 | ||
100% fast oxygen | ||
Vaporizer | ||
Brand | Drager and Penlon available | |
Locking | Vaporizer with interlocking system (Optional: Two vaporizers) | |
Automatic recognition | Anesthesia machine able to automatic recognize halogenated gases | |
Power (No isolation transformer) | ||
External AC power supply | ||
Input voltage | 100~240 V~/ 100~120V~ | |
Input current | 3.5~8.5 A/8.5 A | |
Input frequency | 50/60 Hz | |
Leakage current | < 500μA | |
Auxiliary output supply | ||
Output voltage | 100~240 V~/ 100~120V~ | |
Output frequency | 50/60 Hz |