Vacuum Autoclaves Horizontal Double Door Hospital Sterilizer, Double Door Sterilizer

Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Certification: ISO13485
Electric Tension: 220V
LCD Display: Without LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MED-WG 0.25
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Double Door Hospital Sterilizer
Autoclave Steam Sterilizer
Place of Origin
Guangdguangdong, China (Mainland)
Air Removal
Pulse Vacuum (Can Be Set 3-9times)
Drying
Vacuum Drying
The Material of The Shell
Fully Stainless Steel
Adding Water Automatically
Standard
Door Lock
Fully Automatically, Double Door Interlock
Outer Size(L*W*H)
1100*1300*1700mm
Minimum Installation Room(L*W*H)
2200*2300*2200mm
Vacuum Autoclave
Double Door Sterilizer
Transport Package
Standard Package
Specification
CE, ISO
Trademark
Med Equipment
Origin
Guangdong, China (Mainland)
Production Capacity
10000 Sets/Year

Product Description

Vacuum Autoclaves horizontal double door hospital sterilizer, double door sterilizer

WG series pulse vacuum autoclave
 
MED-WG0.25

Vacuum Autoclaves Horizontal Double Door Hospital Sterilizer, Double Door Sterilizer

Parameter
Air removal Pulse Vacuum (can be set 3-9times)
Drying Vacuum drying
Stand by or not yes
The material of the shell Fully stainless steel
Adding water automatically standard
Exhausting water  automatically standard
Door lock Fully automatically, double door interlock
Outer size(L*W*H) 1100*1300*1700mm
Minimum installation room(L*W*H) 2200*2300*2200mm
Door Structure Double door motorized door
Sterilizing room 288L±5%
Sterilizing chamber shape Horizontal      type,     304    type,     welding,
 
mechanical polishing,0.4
Chamber size (L*W*H) 800*600*600mm
Net.Weight 900kg
Gross.Weight 1050kg
Package  size(L*W*H) 1300*1450*2100mm
Water tank capacity 58L
Average water consuming for each cycle 40KG
Maximum temperature of the water tank 136ºC
Design pressure 0.245Mpa
Design temperature 139ºC



 

 
Working power supply AC380V,50HZ,
Power consumption ≤28KW
Heat average ≤+2ºC
Steam pressure 0.3-0.5Mpa
Water resource pressure 0.1-0.3Mpa
Compressed air 0.5-0.8Mpa
Power fluctuate ±10%
Control system Main controller PLC,microcomputer touch screen,printer      and   the        other                            control
elements
Display 7"    colorful
 
SIEMENS
screen, touchable from
With printer yes
TRAYS  (standard allocation) 2
Tray size(L*W*H) 550*760*50mm
Sterilizing cycle 5 fixed sterilizing cycles+2 fixed testing cycles+1  fixed debug  cycle+1  fixed fluid
cycle+ free setting cycle
Sterilizing items Solid,fluid(heat resistance and placed into
 
un sealed fluid)
Sterilizing  temperature(selectable) From 105ºC to 134ºC


 
 
 
 
 
 
PROCESS
 
The regular setting of the device is divide into solid and fluid for the users' choose, and also with the manual procedure for operators.
 
 
 
 
l   The chart for the sterilization to the solid objects:Applied to the instruments, dressings, utensils and other items.
 
 

 
 
 
 
 
 
l   The introduction for the sterilization to the fluid, applied to the fluid placed into the non-sealed media which can not bear the high heat and vacuum process.
 
 

 
 
 
 
 
 
 
 
 
 
l   Manual procedures: According to the special needs of the sterilized items and the different abnormal operating conditions, the users can set the

parameters under this program to call the device all reasonable combination features.
 
 
 
 
l  

Sterilizing items
Pre-h eating vacuum Heat mins Sterilizi
 
ng
Dryin g time Cycl e time Remard
times mins Temp
eratur e
Ti me
Naked
 
instrument
5 3 10 5 134ºC 3 0 23 Without drying
Naked
 
instrument
5 3 10 5 134ºC 3 2 25 drying  , load  <
 
30KG
packaged
 
instrument
5 3 10 5 134ºC 3.
 
5
15 38.5 drying  , load  <
 
30KG
Packaged
 
instrument
5 3 10 5 134ºC 15 20 55 drying  , load  <
 
30KG
Heat   sensitive items                   and
textile
5 3 10 5 121ºC 20 20 60 drying  , load  <
 
10KG
fluid 5 0 0 10 121ºC 30 Exhau 50 heat  resistance  or

The chart for the time of each cycle: (Time: min)

 







sting
 
time 5

unsealed fluid
BD test 5 3 10 5 134ºC 3.
 
5
5 29.5 Testing procedure(in accordance                         with the requirement of
the testing bad)
Vacuum test Sucking  the air             till the            vacuum        rate
reach     -86Kpa
In the following 10 mins, the decrease allowable pressure each min is ≤ 0.13KPA, or the total decrease
pressure for 10 min is ≤1.3KPA.
Debug cycle For the use the the factory inspection and repairing
Free cycle the  sterilizing  parameter  can  be  set  freely  in  accordance  with   different
 
requirement .
 
 
 
Atten: The steam generates time is not included .

Vacuum Autoclaves Horizontal Double Door Hospital Sterilizer, Double Door Sterilizer
Vacuum Autoclaves Horizontal Double Door Hospital Sterilizer, Double Door Sterilizer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now