Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model : MC-DYM-02 / MC-HD01
What is the detail of our hemodialysis machine?
Main technical parameter
Volume (length× width ×height):370mm×340mm ×1570mm
Weight: about 90kg
Power supply voltage: AC220V±10%
Frequency: 50HZ ~ 60 HZ
Power: 1500W
Blood pump/spare pump
Flux: 15 ~ 340ml/min (D 6mm)
Flux: 20 ~ 460ml/min (D 8mm)
Heparin pump:
Flux: 0.1ml/h~10ml/h(±5%)
Flux: Precise: 0.1ml/h
Injector size: 20ml/30ml/50ml 10ml/20ml/30ml (selectable)
Arterial pressure
display scope:-300mmHg~+300mmHg (±10mmHg)
Venous pressure
display scope:-50mmHg~+300mmHg (±10mmHg)
Dialysate flow:300ml/min~800ml/min linearity adjustable(+10%)(-5%)
Temperature:35.0ºC~39.0ºC
Resolving rate:0.1ºC
Conductivity:13mS/cm~15.5mS/cm(±0.1 mS/cm)
UF flow scope: 0~1800ml/h(±30ml/h )
0~4000ml/h(optional)
ISO UF flow scope:0~2000ml/h(±30ml/h)
TMP
Scope:-100mmHg~+600mmHg (±20mmHg)
Blood leakage monitor: over 1ml blood per liter dialysate (flow:500ml/min)
Blood level monitor: ultrasonic sensor
Air bubble monitor
Infrared and response threshold value:Single air bubble of 200u I exists when Blood flux is 200ml/min
Inflow pressure:0MPa~0.6MPa
Inflow temperature: 5ºC~30ºC
Environment temperature: 10ºC~30ºC, Relative humidity≤70%
Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid)
Hot rinse: 80ºC
Back-up power supply: last for 15-30min after electric-cut.
Function
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.
Touch screen was equipped and it can show Naand UF profiles;In addition,the functions ie.backup power supply,Kt/V,HCO3adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.
What is the clinical application of our Kidney Dialysis Machine?
Clinical Application
√ Hemodialysis Therapy
√ Pure ultrafiltration Therapy
√ Hemoperfusion Therapy
√ Plasma exchange Therapy
√ Na+and UF profiling
Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect.
Kt/V function
The sufficiency of dialysis can be reflected by Kt/V.
HCO3 adjustment function:
Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient's state of illness.
Backup power-supply:
It can last for 15-30 minutes after power cut off.
Pyrogen filter port
Completely filtrating the remained bacteria and endotoxin.(optional)
Net connection
One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)
Model : MC-DYM-02 & MC-HD05
Function
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.
Touch screen was equipped and it can show Naand UF profiles;In addition,the functions ie.backup power supply,Kt/V,HCO3adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.
What is the clinical application of our Kidney Dialysis Machine?
Clinical Application
1. Hemodialysis Therapy
2. Pure ultrafiltration Therapy
3. Hemoperfusion Therapy
4. Plasma exchange Therapy
5. Na+and UF profiling
Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect.
Kt/V function
The sufficiency of dialysis can be reflected by Kt/V.
HCO3 adjustment function:
Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient's state of illness.
Backup power-supply:
It can last for 15-30 minutes after power cut off.
What is the detail of our hemodialysis machine?
Main technical parameter
Volume (length× width ×height):370mm×340mm ×1570mm
Weight: about 90kg
Power supply voltage: AC220V±10%
Frequency: 50HZ ~ 60 HZ
Power: 1500W
Blood pump/spare pump
Flux: 15 ~ 340ml/min (D 6mm)
20 ~ 460 ml/min (D 8mm)
Heparin pump:
Flux: 0.1ml/h~10ml/h(±5%)
Precise: 0.1ml/h
Injector size: 20ml/30ml/50ml 10ml/20ml/30ml (selectable)
Arterial pressure
display scope | -300mmHg~+300mmHg (±10mmHg) |
Venous pressure
display scope:-50mmHg~+300mmHg (±10mmHg)
Dialysate flow:300ml/min~800ml/min linearity adjustable(+10%)(-5%)
Temperature:35.0ºC~39.0ºC
Resolving rate:0.1ºC
Conductivity:13mS/cm~15.5mS/cm(±0.1 mS/cm)
UF flow scope: 0~1800ml/h(±30ml/h )
0~4000ml/h(optional)
ISO UF flow scope:0~2000ml/h(±30ml/h)
TMP
Scope:-100mmHg~+600mmHg (±20mmHg)
Blood leakage monitor: over 1ml blood per liter dialysate (flow:500ml/min)
Blood level monitor: ultrasonic sensor
Air bubble monitor
Infrared and response threshold value:Single air bubble of 200u I exists when Blood flux is 200ml/min
Inflow pressure:0MPa~0.6MPa
Inflow temperature: 5ºC~30ºC
Environment temperature: 10ºC~30ºC, Relative humidity≤70%
Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid)
Hot rinse: 80ºC
Back-up power supply: last for 15-30min after electric-cut.
Pyrogen filter port
Completely filtrating the remained bacteria and endotoxin.(optional)
Net connection
One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)
Our hemodialysis machine for kidney in different hospitals worldwide, Paraguay, Nigeria, South Africa, Zimbabwe, Uganda, Kenya, Malaysia etc.
Our hemodialysis in Paraguay
Our hemodialysis in Nigeria
Our hemodialysis in Uganda
Our hemodialysis in Kenya
Our hemodialysis in Zimbabwe
Our hemodialysis in South Africa
Our hemodialysis in Malaysia
Hemodialysis Center